Assessing the Influence of Asymmetric Modes on the Reliability Indicators of Distribution Systems (Запис № 1237)

МАРК-запис
000 -LEADER
Маркер (контрольне поле довжиною 24 байти) 02767aab a2200301 i 4500
001 - КОНТРОЛЬНИЙ НОМЕР
Контрольне поле 1237
003 - ІДЕНТИФІКАТОР КОНТРОЛЬНОГО НОМЕРА
Контрольне поле UA-KpCNTU
005 - ДАТА І ЧАС ОСТАННЬОЇ УГОДИ
Контрольне поле 20250530102836.0
008 - ЕЛЕМЕНТИ ДАНИХ ФІКСОВАНОЇ ДОВЖИНИ - ЗАГАЛЬНА ІНФОРМАЦІЯ
Маркер (контрольне поле довжиною 24 байти) 250304b un |||| |||| 00| 0 rus d
040 ## - ДЖЕРЕЛО КАТАЛОГІЗАЦІЇ
Transcribing agency ЦНТУ
Original cataloging agency UA-KpCNTU
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title rus
100 ## - MAIN ENTRY--PERSONAL NAME
Ім’я особи Erhan F.
245 ## - TITLE STATEMENT
Назва Assessing the Influence of Asymmetric Modes on the Reliability Indicators of Distribution Systems
Носій [Текст]
Statement of responsibility, etc. / F. Erhan, D. Voinesco
250 ## - ЗАЯВА ПРО ВИДАННЯ
Відомості про видання Конструювання, виробництво та експлуатація сільськогосподарських машин
Remainder of edition statement Вип. 51.
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Дата видання, розповсюдження тощо 2021.
300 ## - PHYSICAL DESCRIPTION
Розмір С. 88-94.
500 ## - ЗАГАЛЬНА ПРИМІТКА
General note The power electric distribution systems (PEDS) possess a great dynamics of development. Thanks to this phenomenon in the power electric distribution systems (PEDS) the probability of apparatus of asymmetrical regimes increase monotonously. As a result of this reliability of the functioning of the power electric equipment installed in the electric knots changes. The asymmetrical regimes in the power electric distribution systems<br/>(PEDS) accompanied by the short circuit current are a function of a row determinate is a vague factor of probabilistic nature. Coming from it follows that the investigation of the influence of the asymmetrical regimes accompanied by the current of the short circuit on the reliability of the Power Electric Distribution Systems (PEDS) is one of the most important problems of the development the Power Electric Distribution Systems. The short circuit currents influence the structural and functional reliability of distribution networks and at the reliability of electrical equipment installation. The dynamics of changes in the levels of short circuit currents in electrical networks depends on the rate of change of the re-recovering voltage at the short circuit point on the power supply side and on the load side, as well as on the magnitude and rate of power change at the short circuit point on the power source side and on the load side.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term current of the short circuit
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Asymmetrical regimen
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Power electric distribution systems
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Reliability of electrotehnical equipment
700 ## - ДОДАТКОВИЙ ОПИС — ІМ’Я ОСОБИ
Ім’я особи Erhan F.
700 ## - ДОДАТКОВИЙ ОПИС — ІМ’Я ОСОБИ
Ім’я особи Voinesco D.
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Кропивницький : ЦНТУ, 2021.
Назва Конструювання, виробництво та експлуатація сільськогосподарських машин. Вип. 51
Контрольний номер запису 348
Міжнародний стандартний номер серіального видання (ISSN) 2414-3820
856 ## - ЕЛЕКТРОННЕ РОЗМІЩЕННЯ І ДОСТУП
Універсальний ідентифікатор ресурсу <a href="https://dspace.kntu.kr.ua/handle/123456789/11897">https://dspace.kntu.kr.ua/handle/123456789/11897</a>
Текст посилання Репозитарій Центральноукраїнського національного технічного університету
942 ## - Додаткові дані (Коха)
Код системи класифікації для розстановки фонду Універсальна десяткова класифікація (УДК)
Тип одиниці Статті
Suppress in OPAC

Немає доступних примірників.