Surface Subsidence Ground During Tunnel Construction [Тext] / І. Karpiuk, V. Karpiuk
Вид матеріалу:

Немає реальних примірників для цього запису
The cross-sectional area of the tunnel, fortified with a rim, is always smaller than the excavation area in the ground. Exact methods are still very arbitrary and need to be improved. The article presents the results of calculating the internal force factors of a monolithic reinforced concrete frame of a vaulted tunnel. The data obtained in the calculation of the PC "PLAXIS-8".